All boards
18 boards ran 16,316 evaluations in the last 30 days. 112 first attempts failed; 43 passed on retry. 68 evaluations still failed after retries, most on Juno. 1 of 1,398 change, patchset and board pairs evaluated had a failed boot on these boards.
Owner groups
Boards grouped by owner. A group page scopes every number to its boards.
- Arm 3 boards
- Google ChromeOS 6 boards
- NXP 2 boards
- STMicroelectronics 5 boards
The bench
One tape per board: evaluations per day, stacked by final outcome. Each tape has its own scale, topped by its busiest day, so compare boards by the totals beside their names. Failures sit on top as caps.
- Pass
- Passed on retry
- Lab
- Code
- Cancelled
- Unclassified
- Asurada (MT8192)MT8192334No failures
- B-U585I-IOT02ASTMicroelectronics234No failures
- Cherry (MT8195)MT8195292No failures
- Corsola (MT8186)MT8186290No failures
- FRDMMCXN947NXP35No failures
- Geralt (MT8188)MT8188290No failures
- JunoArm12,659Failures on 3 days
- LPCXpresso55S69NXP41No failures
- Musca-BArm199No failures
- N1SDPArm455No failures
- Nucleo-U3C5ZI-Qnucleo-u3c5zi-q44No failures
- RPi (BCM2837)BCM2837333No failures
- Rauru (MT8196)MT8196211No failures
- STM32H573I-DKSTM32H573I234No failures
- STM32MP15X-EvalSTM32MP15X287No failures
- STM32U3C5ZI-QSTM32U3C5ZI2No failures
- STM32WBA65I-DK1STM32WBA65I82No failures
- Trogdor (SC7180)SC7180294Failures on 5 days
Changes with a failed boot on this board
Distinct change and patchset pairs whose evaluation on the board (Allow-CI+2 for TF-A, linked runs for TF-M) still failed its boot check after retries, out of pairs with a boot verdict. Only runs whose Jenkins lineage was captured can count, so each board shows the share of its evaluations linked to a change. Gerrit votes are not collected, so this is not a count of blocked changes.
Failed after retries
CI evaluations with a final code, lab or unclassified failure, newest first; 25 of 68 shown. Health checks and manual runs are never listed here.
Fleet health
Health checks from the last 7 days, whatever the window above. They are not CI results and never count towards any rate on this page. Check units means at least one unit's latest health check failed.
58 devices across 18 board types. Devices are units that ran any LAVA job, health checks included, in the last 30 days, whatever the window or project above. Every board type that is not retired counts, including those with health checks only.